Clearwater 18 Person Sewage Treatment System, Gravity

Clearwater 18 Person Sewage Treatment System, Gravity

Product Ref: E018G10A0B

Free Delivery HIAB Available Below Ground

Home Delivery

UK mainland delivery from FREE ex VAT

check delivery cost

Choose option:
Choose option:

updown
from £2,798.00 ex VAT
(£3,357.60 inc VAT)
Product Description

18 Person Clearwater Sewage Treatment System - Gravity Discharge

Clearwater E-Range is a sewage treatment system from Clearwater that’s fully compliant with building regulations and certified to EN 12566. The tank will treat effluent from a domestic or commercial property to a certain level as specified and tested under European Performance Standard EN 12566. Tested for pollution removed from effluence, the power used to do this, and the level of maintenance required by this E6 sewage treatment plant, this plant is a cost-effective, low-maintenance solution for off-mains properties.

Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological process for the treatment of sewage.

Three distinct process stages take place within the single tank:
First, coarse solids are filtered and retained for gradual breakdown. Then the resulting liquid is continuously distributed over a plastic suspended filter by an integral lift, powered by a remotely sited blower. Finally, the solids are allowed to settle and, under normal domestic conditions, treated water of 20mg/l BOD, 30mg/l S.S., 20mg/l Ammonia can be achieved.

Benefits:
• Superior performance rating.
• Subject to consent and site conditions, the plant can discharge directly to a watercourse.
• No mechanical or electrical components within the plant - low running and maintenance costs.
• Low level visibility with a lockable child-proof pedestrian duty cover - safe for children and pets.
• Controlled ventilation - minimises risk of odour nuisance.
• Package options to all requirements and needs.
• Easy to install and maintain with annual desludging.

Certificated to European Standard EN-12566. In 2005, a new European Performance Standard was introduced. EN-12566 requires manufacturers to submit their product to a testing regime that accurately measures the performance of treatment plants up to 50 population. These tests identify how much pollution the treatment plant removes from the sewage, what level of maintenance is required, and what power is absorbed. By holding EN-12566 certification, the Clearwater treatment plant is approved for an exemption from a permit to discharge under the new EPP2 environmental legislation.

*Free Survey subject to distance - Please contact us from more information

Do you require Commissioning?
To ensure your system operates to maximum efficiency, we recommend tried and tested Commissioning by our own British Water and Safe Building trained engineers.
Our unrivalled knowledge means that we are best placed to carry out bespoke assessments to get your system up and running. The commissioning will also provide you with a unique checklist against your system, ensuring your complete peace of mind and reassurance that your system's mechanical and electrical components are in good working order.

Whats included in the commissioning? Click here for more information.
The below is carried out out by a Clearwater Service Engineer, and will only be checked if the unit has been installed in line with the provided installation guidelines.

  • Check Plant is level, 5mm tolerance
  • Confirm the ground around the plant is level, flat and that the lid securely fastens
  • Confirm the panel has been mounted correctly
  • Make the required connections to the panel using correct glands
  • Make all electrical connections within the tank
  • Ensure all safety guards are fitted
  • Sat all greasomatics within the plant (if applicable)
  • Check belt/chain tension and alignment
  • Check pump float activates freely (pumped discharge only)
  • Check operation of sludge return pump (nitrification plants only)
  • Check direction of disc pack
  • Check levels within unit
  • Test and set any Alarms supplied with the unit


On completion they will provide a site specific commissioning certificate

 

Delivery

Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK,G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

Our lead times should only be used as a guide and are subject to change.

Offloading

Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

We recommend installers and/or plant hire & materials for install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

If you have any questions regarding your delivery please contact the Sales Team on 01643 703358.

Returns Information

Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to 4.6 & 4.7. **

Please be aware that returning a tank can be complicated and expensive so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

If you wish to return goods, please complete the form on this page to provide further information.

Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

Please click here to request a return

Product Specification

  • Product Code: CL
  • Free Delivery: Free Delivery
  • HIAB Available: HIAB Available
  • Tank Use: Below Ground
  • Weight: 0.010kg, 445.000kg
  • Dimensions: H:2600mm
  • Diameter: 2700mm