Pump Specification

Model Inlet/Outlet Size (mm) kw Voltage Flow Rate (l/min) Head (m) Dimensions (WxLxH) Dry Weight (kg)
ENM20 20 0.37 110 35 22 120x248x190 5.9
ENM20 20 0.37 230 35 22 120x248x190 5.9
ENM25 25 0.45 110 55 13 141x318x190 9
ENM25 25 0.45 230 55 13 141x318x190 9
ENM30 30 0.75 110 90 16 162x376x209 11.9
ENM30 30 0.75 230 90 16 162x376x209 11.9
ENM40 40 0.9 110 155 18 162x376x209 13.8
ENM40 40 0.9 230 155 18 162x376x209 13.8
ENM50 50 1.5 230 260 24 202x431x236 20.7
Frame**           260x370x290 add 3.2kg

 

EN(M)- EN(T)  Type  Impeller Body  
Regenerative Turbine Alloy  
         
Pump Inlet/Outlet Front Cover Impeller Pump Body
Brass Brass Brass Brass
Shaft Lip Seal Back Cover Motor Support
S/S 316 NBR S/S 304 Cast Aluminium
         
Motor Poles Enclosure Insulation  
2 pole IP44 Class F  

Downloadable Documents

Product Description

Chemical Transfer/Circulation Pump

General use pumps, these are self priming and easily moved around, providing excellent portability. They come with a forward and reverse switch for filling and emptying applications, and obviously switching in between. As standard, these pumps come freestanding with predrilled holes for you to mount it.

There is an option of a frame to be included with the cost for extra protection for the pump and ease of moving the pump around.

Perfectly suited to the transfer and circulation of water, seawater, juices, diesels, transformer oil and mild chemicals. These pumps MUST NOT be used to pump petrol, solvents or any other liquid that has a low flash point.

We would always recommend if you had any doubts over the suitability of this pump for your needs to please contact us by email. We will need a copy of your MSDS information emailed to sales@tanks-direct.co.uk, and we can check the suitability for you with the manufacturers.

Please see Pump Specification tab for dimensions of each individual pump. 

Delivery

All our transfer pumps are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.


 

 

Delivery

Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

Our lead times should only be used as a guide and are subject to change.

Offloading

Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

HIAB

HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.

If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.

Returns Information

Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **

Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.

All Items must be returned unused, refunds cannot be issued for used or previously installed items.

Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

If you wish to return goods, please complete the form on this page to provide further information.

Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

View Tanks Direct's return policy now.

You may also like...

People who bought this also bought...