305 Litre Single Pump CAT5 Booster Set

 

Product Ref: CAT5/S/305

HDPE (High density polyethylene) Upright
  • Volume: 305ltr
  • Dimensions: L:670mm W:610mm H:1540mm
  • Estimated Lead time:5 - 7 working days

    Home Delivery

    UK mainland delivery from FREE ex VAT

    check delivery cost

    updown

    What does the term Category/ CAT5 mean?

    The Water Supply (Water Fitting) Regulations 1999 provides five backflow prevention categories dependent on the risk level of the water use.

    The regulations require back-flow prevention devices to prevent the water on the premises being drawn backward into the public drinking water supply. Backflow may occur in a number of situations, including burst pipes in the street or cross connection of the mains water supply with pressurised supplies on the premises. An assessment needs to be made of the potential dangers to health of the backflow – if the backflow water comes from a butcher’s shop it is more likely to be contaminated than a newsagent.

    In the legislation, fluid risk category 5 covers the following areas:

    Fluid which represents a serious health hazard because of the concentration of pathogenic organisms, radioactive or very toxic substances, including any fluid which contains –

    faecal material or other human waste:

    butchery or other animal waste: or

    pathogens from any other source.

    To provide category 5 compliance, a break tank has a category ‘AB’ air-gap fitted and a pump which re-pressurises the water.

    Product Description

    305 Litre Single Pump CAT5 Booster Set

    The CAT 5 booster set also know as Backflow prevention booster set incorporates a 305 Litre GRP WRAS approved break tank complete with a raised ball valve chamber with an AB air gap to WRAS approved regulations.
     

    Applications include:

    • Laboratories
    • Veterinary Surgeries
    • Bin Washdown
    • Mortuaries
    • Abattoirs
    • Bib Tap


    Operation

    The CAT 5 Booster set is designed to monitor the system pressure. As the demand increases the pressure will fall and the pump will start to run until the demand has stopped and the pressure increases.
     

    Pump Specification

    Multistage pump complete built in pressure switch, 230 volt single phase supply.

     

    Technical Specifications

     

    • Single Pump Packaged Booster Set and CAT5 Break Tank.
    • Fixed Speed Pressure Pump - Variable speed optional upon request.
    • Pre-assembled for easy installation.
    • Wet/Pressure tested prior to despatch.
    • Quiet operation, less than 50 decibels.
    • Compact design, narrow width ideal for access through doorways.
    • WRAS Approved water storage tank manufactured from GRP with 25mm insulation.
    • WRAS Approved 3
    • 4" High flow ball valve fitted.
    • 1 Phase 230 Volt supply.
    • Low Water Level Protection.
    • WRAS Approved fully adjustable system pressure reducing valve fitted.
    • Maximum allowable static head 12 metres.



    Tanks Direct also supply variable domestic & commercial twin and triple pumps, please contact us on 01643 703358.

     

    Delivery

    All our Booster sets are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.

    If you require any specific requirements regarding delivery, please call us before order is placed, where we will try and accommodate this facility for you.

     

    Image is for display purposes only, tank could differ in size, please check the data sheet re dimensions.

    Product Details

    • Product Code: DPT
    • Material: HDPE (High density polyethylene)
    • Shape: Upright

    Delivery

    Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

    Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

    Our lead times should only be used as a guide and are subject to change.

    Offloading

    Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

    We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

    HIAB

    HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.

    If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.

    Returns Information

    Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **

    Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.

    All Items must be returned unused, refunds cannot be issued for used or previously installed items.

    Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

    If you wish to return goods, please complete the form on this page to provide further information.

    Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

    Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

    Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

    View Tanks Direct's return policy now.

    People who bought this also bought...