Klargester BioAir 2 Sewage Treatment Plant - 6 Person

 

Product Ref: BIA2UPPK

Customer Offloading Fast Delivery Free Site Survey HIAB Available MDPE Stock tank Below Ground, Sewage Below Ground, Sewage
  • Weight: 170.000kg
  • Dimensions: L:2500mm H:2105mm
  • Diameter: 1540mm
  • Estimated Lead time 3-5 working days

    Home Delivery

    UK mainland delivery from FREE ex VAT

    check delivery cost

    Choose option:
    Choose option:

    updown

    Specification

     

     

    BioAir

     

    Model

     

    BioAir 2

     

    Population Equivalent

     

    Unit

     

    6

     

    Daily Flow

     

    m3/d

     

    0.9

     

    Daily Load

     

    kg BOD5/d

     

    0.36

     

    Measurements

     

    Outlet invert

     

    mm

     

    555-855

     

    Diameter

     

    mm

     

    1540

     

    Length

     

    mm

     

    2500

     

    Installation depth

     

    mm

     

    1805-2105

     

    Inlet invert

     

    mm

     

    455-755

     

    Inlet pipe work*

     

    mm

     

    Ø110

     

    Outlet pipe work*

     

    mm

     

    Ø110

     

    Material Construction

     

     

     

    MDPE

     

    Unit Weight

     

    kg

     

    170

    MAXIMUM INLET INVERT USING:

    Gravity Units: Max Invert: 1400mm      Pumped Units: Max Invert: 1000mm

    For Inverts from 755 - 1200mm  order 1 X BPAEXT13    

    For Inverts from 1200 - 1400mm order 2 X BPAEXT13  

     

     

    Video

    Product Description

    Klargester BioAir 2 Sewage Treatment Plant for up to 6 People    

    Utilising aerated technology to deliver a high level of water discharge quality, the new Klargester BioAir 2 is one of the most affordable domestic sewage treatment plants on the market today.

    Suitable for shallow dig installations with flexible installation options, the Klargester BioAir 2 is designed with low level and low impact visual footprint. The BioAir 2 is also suitable for use in light duty traffic areas, although external structural design advice will be required before proceeding.

    The BioAir Premium unit is supplied with a Control Panel, PPFDS Alarm, Beacon & High Level Alarm (IPS unit only), whilst the BioAir Economy model is supplied with an Isolator Switch and Failure light.

    Product Benefits: 

    BioAir Economy: 

    • Suitable for shallow dig Installations
    • Suitable for use in traffic areas (structural design advice required by others)
    • Low level visibility
    • No plastic media
    • Improved effluent quality – BOD5 97.5%
    • Third party tested to EN 12566-3
    • Easy to install and operate
    • Supplied with Isolator and Failure light
    • Affordable service plans available
    • Robust and Lightweight
    • BioAir Economy - 12 months warranty* (terms apply)
    • Standard Commissioning Available  

    Additional Benefits with BioAir Premium: 

    • Supplied with a Control Panel, PPFDS Alarm, Beacon & High Level Alarm (IPS unit only)
    • BioAir Premium - 3 Years warranty* (terms apply)
    • Standard or Smart Commissioning Available

     

    Typical Applications

    • Single & Multiple Homes
    • Light Industrial Premises
    • Small Offices
    • Farms
    • Barn Conversion

     

    *Please click on the following link to register your warranty.

    https://www.kingspan.com/gb/en-gb/products/wastewater-management/guarantee

     

     

     

     

     

     

     

     

     

     

     

     

    Product Details

    • Product Code: KLA
    • Customer Offloading: Customer Offloading
    • Delivery: Fast Delivery
    • Diameter: 1540mm
    • Free Site Survey: Free Site Survey
    • HIAB Available: HIAB Available
    • Material: MDPE
    • Stock tank: Stock tank
    • Tank Use: Below Ground, Sewage

    Do you require Commissioning?

    To ensure your system operates to maximum efficiency, we recommend tried and tested Commissioning by our own British Water and Safe Building trained engineers.

    Our unrivalled knowledge means that we are best placed to carry out bespoke assessments to get your system up and running. The commissioning will also provide you with a unique checklist against your system, ensuring your complete peace of mind and reassurance that your system's mechanical and electrical components are in good working order.

    The checks below will be carried out by a Kingspan Service Engineer and will only be checked if the unit has been installed in line with the provided installation guidelines.

    • Check Plant is level, 5 mm tolerance
    • Confirm the ground around the plant is level, flat and that the lid securely fastens
    • Confirm the panel has been mounted correctly
    • Make the required connections to the panel using correct glands
    • Make all electrical connections within the tank
    • Ensure all safety guards are fitted
    • Set all greasomatics within the plant (if applicable)
    • Check belt/chain tension and alignment
    • Check pump float activates freely (pumped discharge only)
    • Check operation of sludge return pump (nitrification plants only)
    • Check direction of disc pack
    • Check levels within unit
    • Test and set any Alarms supplied with the unit

     

    On completion, they will provide a site specific commissioning certificate

    Smart Commissioning – Standard commissioning as scope of works, Inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. 

    Smartserv alerts both Kingspan and designated contacts.  Includes 3 years Kingspan monitoring free of charge.

    Find out more about what's included in the commissioning of your Clearwater pump station and arrange Commissioning, read Kingspan's dedicated guide to Commissioning today.

    *terms and conditions apply

     

     

    Delivery

    Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

    Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

    Our lead times should only be used as a guide and are subject to change.

    Offloading

    Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

    We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

    HIAB

    HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.

    If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.

    Returns Information

    Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **

    Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.

    All Items must be returned unused, refunds cannot be issued for used or previously installed items.

    Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

    If you wish to return goods, please complete the form on this page to provide further information.

    Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

    Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

    Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

    View Tanks Direct's return policy now.

    People who bought this also bought...