THIS ITEM IS UNAVAILABLE. YOU MAY BE INTERESTED IN ONE OF THESE ALTERNATIVES...

Clearwater 400L Compact Sewage Pumping Station
Best Seller
Clearwater 400L Compact Sewage Pumping Station
from £640.00 ex VAT
(£768.00 inc VAT)
EBARA BEST FOUR (M) SUMP PUMP
New Corner Triangle
EBARA BEST FOUR (M) SUMP PUMP
£634.20 £550.00 ex VAT
(£660.00 inc VAT)
FCZ Adblue PumpFCZ Adblue Pump
FCZ Adblue Pump
from £210.00 ex VAT
(£252.00 inc VAT)

Klargester 900L Twin Pumping Station

 

Product Ref: DPSEJ2

Customer Offloading Free Delivery GRP Round Below Ground, Sewage Below Ground, Sewage Twin
  • Volume: 900ltr
  • Weight: 160.000kg
  • Dimensions: H:1580mm
  • Diameter: 900mm
  • Request a quote

    Key Factors to size your Pump Stations

    To size your pump stations they key factors to take into consideration are below

     

     


    • ? Application: domestic, residential or commercial.

    • ? Material application: sewage, effluent or surface water.

    • ? Inlet depth (below ground level).

    • ? Pumping distance and lift.

    • ? Electrical supply.






    •  
    •  
    •  
    •  
    •  

     

     

     

     

    If you require assistance with sizing your Pump station, please give our sales team a ring on 01643 703358.

     

     

    Product Description

    Klargester 900L Twin Pumping Station

    Klargester pumping stations are manufactured from super-tough, low-maintenance GRP, and are engineered with the highest quality parts and fittings.  Supplied with 2 grundfos pumps so that wear is shared between 2 pumps to reduce the impact of normal wear and tear. They are also appropriate where 24 hour storage requirements need to be maintained. Ideal for homes or properties of up to 10 people.

    Product Benefits

    • Made with super-tough, low maintenance GRP for guaranteed durability.

    • Supplied with control panel with options for remote monitoring system.

    • Designed with easy access features for maintenance.

    • Choose from either 110mm or 160mm inlet connections (always supplied at 180 degrees).

    • Lockable covers for optimum security.

    • Quick connection outlet couplings.

    • Reliable performing stainless steel submersible Grundfos pumps

    • High Level Alarm included
     

    Klargester 900L Twin Pump Station Specifications

    Chamber Size (mm) Capacity (L) Tank Material Control Panel High Level Alarm Pump Type
    900 x 1580 900 GRP Included Included Twin

    Product Details

    • Product Code: KLA
    • Colour: Brown
    • Customer Offloading: Customer Offloading
    • Delivery: Free Delivery
    • Diameter: 900mm
    • Material: GRP
    • Shape: Round
    • Tank Use: Below Ground, Sewage
    • Twin or Single: Twin

    Do you require Commissioning?

     

     

     

    Low Cost Commissioning

     

     

     

     

    Benefits:

     

     

     

     


    • Reassurance that your system's mechanical and electrical components are in good working order

    • A warranty period that only starts when your water system is commissioned, not when it leaves the factory (terms and conditions apply)

    • Trouble-free operation of your system from the start


    •  

     

     

     

     

    Find out more about what's included in the Commissioning of your Clearwater pump station and arrange Commissioning, read Kingspan's dedicated guide to Commissioning today.

     

     

     

     

    Smart Commissioning

     

     

     

     

    Standard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. Smartserv alerts both Kingspan and designated contacts.  Includes 3 years Kingspan monitoring free of charge. (T&Cs apply). 

     

     

     

     

    Standard Commissioning

     

     

     

     

    The checks below will be carried out by a Kingspan Service Engineer and will only be checked if the unit has been installed in line with the provided installation guidelines.

     

     

     

     


    • Unit is installed flat and level with safe working area around the perimeter

    • All incoming and outgoing pipework has been connected

    • The control panel has been mounted

    • Permanent electrical supply has been fitted to the panel (extension leads or generator supplies will not be acceptable)

    • The following will then be carried out by an Authorised Service Engineer:

    • Check the system is installed to manufacturer's instruction

    • Fit floats in tank and set the levels

    • Pull float and pump cables through the ducts using drawstring provided

    • Connect pump and float cables to the control panel using appropriate glands (the panel must be within 2 m of the chamber or select “enhanced commissioning”)

    • Check float cable operation and terminate (stop, start, standby, alarm)

    • Check pump rotation

    • Run the pumps via the float switches to ensure correct operation and discharge

    • Test high level alarm and beacon (if applicable)

    • Leave on Auto for future use


    •  

     

     

     

     

    Please note, Kingspan Commissioning covers UK mainland and certain postcode areas only. Please speak to our Team for expert advice on Commissioning.

     

     

     

     

    Service and maintenance

     

     

     

     

    Your pump station should be serviced bi-annually to prevent blockages or obstructions in the inlet or outlet pipes from occurring. Any service and maintenance works need to be carried out by a properly trained professional, with appropriate experience, especially with mechanical and electrical parts. For more information on service and maintenance plans, please give our team a call on 01643 703358. 

     

     

    Delivery

    Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

    Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

    Our lead times should only be used as a guide and are subject to change.

    Offloading

    Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

    We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

    HIAB

    HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.

    If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.

    Returns Information

    Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **

    Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.

    All Items must be returned unused, refunds cannot be issued for used or previously installed items.

    Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

    If you wish to return goods, please complete the form on this page to provide further information.

    Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

    Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

    Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

    View Tanks Direct's return policy now.

    People who bought this also bought...