1 Zone Leakstopper Water Leak Detection Panel

1 Zone Leakstopper Water Leak Detection Panel

Product Ref: Leakstopper1

  • Weight: 0.010kg
  • Estimated Lead time:5 - 7 working days

    Home Delivery

    UK mainland delivery from £15.00 ex VAT

    check delivery cost

    updown
    from £538.00 ex VAT
    (£645.60 inc VAT)
    Product Description

    Leakstopper 1 Zone Water Leak Detection Panel


    Water Leak Detection, sensor based, single zone alarm panel (The LeakStopper1). The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected the alarm panel will trigger an internal buzzer and an LED will start to flash. There are also a number of volt free relays that will switch when water has been detected.

    Water (unless purified) contains contaminants such as ions and salts and it''s these within the water that are conductive. The sensors (conductors) used for leak detection are separated by a carrier and the water acts as a path for very low electrical signal to pass from one to the other. It is this action that triggers the alarm.

    Options: The optional different types of water leak detection sensors:

    Sensor Tape: Available in 1m, 2m, 3m, 5m and 10m lengths. Plug and socket connections mean any length can be made up by simply connecting the various cable lengths together. The tape is most commonly used sensor method and will be used whenever an area needs to be monitored for leaks. If water touches at any point along the length of the tape, the alarm will sound off. A typical example might be a tea point in an office where the alarm panel will be fixed to the wall, the connection cable routed down to underneath one end of the kitchen cupboards. At this point it will be terminated in a start of line junction box and the sensor tape plugged into this. The sensor tape is run under the pipe work under the cabinets and held in place by cable clips. At the end of the sensor tape there is a end of line connector that must be fitted and is used to monitor the connections and cables for faults.

    Sensor Probe: Adjustable height from the floor between 0 and 25mm. Protective cover helps stop accidental damage. Multiple sensors can be linked in series to cover large areas.
    The sensor probe would be used in situations where either only a single point is important (such as a bund) or where a sensor tape might get damaged by foot traffic or some other process. A number of probes can be looped together back to the Leakstopper panel

    Sensor Pad: Ideal for placing in drip trays, under shower trays etc. Little bigger than a matchbox, this sensor can be linked together in series.
    The sensor pad would be used in a drip tray that has been installed under an air conditioning system or under a run of pipework. A number of pads can be looped together back to the Leakstopper panel

    Inline Tee Sensor: The tee sensor would be used to monitor for liquid in an overflow pipe to ensure that the levels do not exceed an amount that would cause concern. The tee sensor when connected to a water leak detection alarm can instruct a valve to switch off the water should liquid be present in the overflow.

    The beacon/sounder: The Beacon/Sounder Alarm can be connected to any of our alarm panels or directly to a float switch. Should the master panel detect a leak or the float switch lift too high, the beacon will flash and the sounder sound. These panels simply plug straight into any of our alarm panels using a 4 core alarm cable. As soon as the master panel has an alarm triggered a signal is sent straight to the Beacon alarm illuminating the ultra bright beacon and sounding the 102dB sounder.

    Summary oF Features:
    Very bright LED beacon
    102 dB sounder
    No local power required as power is taken directly from the master panel. If used independently of our alarm panel, it can be supplied with a 230VAC or a 12 - 24VDC input (this would be the case when used with a float switch)
    Beacon only option for areas where high noise levels are not desirable.
    Automatically resets as soon as the master panel resets.
    IP65 rated enclosure.

    Connections for the Senor Tape option include the Start of line junction box and end of line connector DIN plug

     

    Delivery

    Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

    Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK,G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

    Our lead times should only be used as a guide and are subject to change.

    Offloading

    Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

    We recommend installers and/or plant hire & materials for install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

    If you have any questions regarding your delivery please contact the Sales Team on 01643 703358.

    Returns Information

    Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to 4.6 & 4.7. **

    Please be aware that returning a tank can be complicated and expensive so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

    If you wish to return goods, please complete the form on this page to provide further information.

    Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

    Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

    Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

    Please click here to request a return

    Product Specification

    • Product Code: ENV

    People who bought this also bought...

    105 Litre Upright Water Tank105 Litre Upright Water Tank
    105 Litre Upright Water Tank
    from £72.00 ex VAT
    (£86.40 inc VAT)
    250 Litre Water Tank250 Litre Water Tank
    250 Litre Water Tank
    from £105.44 ex VAT
    (£126.53 inc VAT)

    Bunded work floors for 4 drumsBunded work floors for 4 drums
    Bunded work floors for 4 drums
    from £212.00 ex VAT
    (£254.40 inc VAT)

    4 Drum Spill Pallets, in-line
    Best Seller
    4 Drum Spill Pallets, in-line
    from £150.00 ex VAT
    (£180.00 inc VAT)

    2 Drum Bund Spill Pallet
    2 Drum Bund Spill Pallet
    from £399.00 ex VAT
    (£478.80 inc VAT)
    Stable HayfeederStable Hayfeeder
    Stable Hayfeeder
    £55.00 ex VAT
    (£66.00 inc VAT)